Strona 1 - Replacement Guidebook

1/52 Easy! Smooth! GP-2600 Series→GP4000 Series Replacement Guidebook 3rd Edition 2014.11 Copyright © 2014.11 Digital Electronics Corporati

Strona 2

10/52 Chapter 2 Compatibility of Hardware 2.1 Locations of connector Connector locations on GP-2600 series and GP-4601T are as follows: GP-2600T

Strona 3

11/52 Interface names GP-2601T GP-2600T GP-4601T 1 Power Input Terminal Block (AC/DC type) Power Input Terminal Block (AC type)/ Power Connector

Strona 4

12/52 2.2 Touch Panel specifications For replacing GP-2600 series with GP-4601T, you can select the Matrix type (2-point touch input at the same t

Strona 5 - CHAPTER 5 APPENDIX 50

13/52 2.4 Interface 2.4.1 Serial Interface The pin assignment and the shape of plug/socket connector of GP-2600 series are different from those of

Strona 6

14/52 2.4.4 CF Card Interface GP-4601T is not equipped with a CF card slot. But a SD card slot and a USB interface are installed. In order to use

Strona 7

15/52 2.5.3 Expansion Unit GP-4601T is not equipped with an expansion unit interface. The expansion unit (each kind of unit like CC-LINK Unit) for

Strona 8

16/52 2.8 Power Consumption The power consumption of GP-2600 series is different from that of GP-4601T. AC Type DC Type GP-2600T 50VA or less (A

Strona 9

17/52 Chapter 3 Replacement Procedure 3.1 Work Flow Receive screen data from GP-2600 series. *1 Convert GP-2600 s

Strona 10

18/52 3.2 Preparation Requirements for receiving screen data from GP-2600 series. *1 GP-2600T: PC in which GP-PRO/PBIII for Windows V5.0 or later

Strona 11

19/52 3.3 Receive screen data from GP-2600 series This section explains, as an example, how to receive screen data from GP-2600 series using a tra

Strona 12

2/52 Preface This guidebook introduces the procedures to replace a unit in GP-2600 series with a unit in GP-4601T. Model in use Recommended Su

Strona 13

20/52 (4) In the Communication Port field, select [COM], specify the COM port to which the cable is connected, and click [OK]. If you use a US

Strona 14

21/52 (5) Select the [Transfer] menu and click [Receive...]. (6) Specify the location to save the received screen data at and the project file n

Strona 15

22/52 In case there is no Upload Information “Upload Information” is necessary to receive screen data from GP-2600 series. It needs to be included

Strona 16

23/52 3.4 Convert screen data with the Project Converter Convert a project file (*.prw) for GP-2600 series with the GP-Pro EX’s Project Converter.

Strona 17

24/52 (4) In [Convert-To], designate a GP-Pro EX’s project file (*.prx). Click the [Browse…] button and enter a new [File Name] (e.g.: “Produ

Strona 18

25/52 NOTE When a convert-to file exists, the window that confirms whether or not to overwrite the file is displayed.

Strona 19

26/52 (5) Click [Convert] and start the conversion. (6) If you are asked about the [Convert-To] type as shown below, select a replacement model’

Strona 20

27/52 If an error message is displayed during conversion If an error message is displayed during conversion, refer to [Project Converter Error M

Strona 21

28/52 (7) After conversion, the [Save convert information] dialog box appears. If you click [Save], you can save the conversion information in a C

Strona 22

29/52 Convert GP-PRO/PBIII for Windows “Destination CF Card Folder” If you convert a project file (*.prw) with a destination CF card folder design

Strona 23

3/52 GP4000 Series Model Number GP4000 series model number partly differs depending on a specification. Before placing an order, please make sur

Strona 24

30/52 3.5 Transfer screen data to GP-4601T Transfer the project file after conversion to GP-4601T. You can transfer data to GP-4601T via; ・ A USB

Strona 25

31/52 (1) Connect your PC and GP-4601T with a USB transfer cable (model: CA3-USBCB-01). If the driver of the cable has not been installed on your

Strona 26

32/52 (2) Turn on the power of GP-4601T. The “Initial Start Mode” screen will appear on the display unit. After transferring a project file once,

Strona 27

33/52 (4) Make sure that the [Device] in the “Transfer Settings Information” is set to [USB]. If not, click the [Transfer Setting] button to open

Strona 28

34/52 (7) When transfer is completed, the status displayed in the dialog box will change from [Transferring] to [Complete Transfer]. Click [Close]

Strona 29

35/52 3.6 Differences of software 3.6.1 Differences after conversion Check the differences of screen data after conversion from GP-PRO/PBIII to GP

Strona 30

36/52 25 Compatibility of Ladder Monitor 26 Compatibility of J Tag and R Tag 27 Converting Screen Data of DOS 28 Compatibility of Standard Font

Strona 31

37/52 Chapter 4 Communication with Device/PLC 4.1 Driver list More connectable drivers will be added. For the devices/PLC each driver supports,

Strona 32

38/52 4.2 Shapes of COM ports GP-2601T GP-2600T GP-4601T COM1 D-Sub 25 pin (socket) RS-232C/422 D-Sub 9 pin (plug) RS-232C COM2 - D-Sub 9 pi

Strona 33

39/52 4.3 Signals of COM ports 4.3.1 Signals of COM1 For GP-2600 series RS-232C or RS-422 (socket)

Strona 34

4/52 Contents PREFACE 2 SAFETY INFORMATION 2 HAZARD OF OPERATOR INJURY, OR UNINTENDED EQUIPMENT DAMAGE 2 GP4000 SERIES MODEL NUMBER 3 CONTENT

Strona 35

40/52 For GP-4601T RS-232C (plug) *1: RI and VICC of Pin 9 are switched on the software. VCC Output is not protected from overcurrent. Plea

Strona 36

41/52 4.3.2 Signals of COM2 For GP-2600T RS-232C (plug) For GP-2601T N/A For GP-4601T RS-422/485 (plug)

Strona 37

42/52 4.4 Multilink Connection For GP-4601T, some communication drivers do not support multi-link connection (n:1) via RS-422. When converting the

Strona 38

43/52 4.6 Cable Diagram at the time of replacement The connection cable for GP-2600 series can be used for GP-4601T. But please note that

Strona 39

44/52 4.6.1 When using a RS-232C connection cable GP-2600 series System Configuration (connecting to COM1) GP-4601T System Configuration (connec

Strona 40

45/52 * For GP-2600T only: GP-2600T System Configuration (connecting to COM2) GP-4601T System Configuration (co

Strona 41

46/52 4.6.2 When using a RS-422 connection cable GP-2600 series System Configuration (connecting to COM1) GP-4601T System Configuration (connect

Strona 42

47/52 NOTE When using a terminal block adapter (GP070-CN10-O), we recommend you to replace it with a terminal block conversion adapter (PFXZCBADTM

Strona 43

48/52 When using Mitsubishi A/QnA series(CPU Direct) connection cable(GP2000-CBLA/5M-01) * Including User-created cable 9/25-pin Conversion Cab

Strona 44

49/52 When using Mitsubishi FX series(CPU Direct) connection cable(GP2000-CBLFX/5M-01, GP2000-CBLFX/1M-01)

Strona 45

5/52 2.5.5 ISOLATION UNIT 15 2.6 POWER CONNECTOR 15 2.6.1 AC POWER SUPPLY TYPE 15 2.6.2 DC POWER SUPPLY TYPE 15 2.7 BACKUP BATTERY 15 2.8 POW

Strona 46

50/52 Chapter 5 Appendix 5.1 Changing the setting of the external media to use If a CF card has been used for GP-PRO/PBIII, after GP-2600 series i

Strona 47

51/52 [Solution] 1. Change the SD Card setting to the USB storage setting following the steps below. <Procedure> i. Click [Project]->[In

Strona 48 - GP4000 series

52/52 NOTE ・ To see how the tags or the parts of GP-PRO/PBIII for Windows are replaced on GP-Pro EX, refer to [OtasukePro!] “Feature Comparison be

Strona 49

6/52 Chapter 1 Specification Comparison 1.1 Specifications of GP-2600T and GP-4601T GP-2600T GP-4601T Display Type TFT Color LCD Display Colo

Strona 50 - Chapter 5 Appendix

7/52 Ethernet I/F 10BASE-T UP! 10BASE-T/100BASE-TX CF Card I/F ✔ - →See 2.4.4 SD Card I/F - NEW! ✔ USB I/F Type A - NEW! ✔ →See 2.3 Type mini B To

Strona 51

8/52 1.2 Specifications of GP-2601T and GP-4601T GP-2601T GP-4601T Display Type TFT Color LCD Display Colors, Levels 256 colors (without blin

Strona 52

9/52 Ethernet I/F - NEW! 10BASE-T/100BASE-TX CF Card I/F ✔ - →See 2.4.4 SD Card I/F - NEW! ✔ USB I/F Type A - NEW! ✔ →See 2.3 Type mini B Tool Con