Chapter 2 - Specifications
GP-2400/2500/2600 Series User Manual 2-7
2.3 Interface Specifications
2.3.1 Serial Interfaces (COM1)
Recommended Connector: Dsub25pin plug XM2A-2501<made by OMRON>
Recommended Cover: Dsub25pin cover XM2S-2511<made by OMRON>
Jack Screws: XM2Z-0071<made by OMRON>
Use rough metric type M2.6x0.45 p threads used to secure the cable’s set
screws.
Recommended Cable: CO-MA-VV-SB5P x 28AWG <made by HITACHI Cable
Ltd.>
To confirm your PLC’s connection specifications , refer to
Pro-Designer On-line Help
Pin Assignments Pin # Signal Name Condition
1 FG Frame ground
2 SD Send data (RS-232C)
3 RD Receive data (RS-232C)
SIO 4 RS Request send (RS-232C)
5 CS Clear send (RS-232C)
6 DR Data Set Ready (RS-232C)
7 SG Signal ground
8 CD Carrier detect (RS-232C)
9 TRMX Termination (RS-422)
10 RDA Receive data A (RS-422)
11 SDA Send data A (RS-422)
12 NC No connection (Reserved)
13 NC No connection (Reserved)
14 VCC 5V±5% output 0.25A
15 SDB Send data B (RS-422)
16 RDB Receive data B (RS-422)
17 RI Ring Indicate (RS-232C)
18 CSB Clear send B (RS-422)
19 ERB Enable receive B (RS-422)
20 ER Enable receive (RS-232C)
21 CSA Clear send A (RS-422)
22 ERA Enable receive A (RS-422)
23 NC No connection (Reserved)
24 NC No connection (Reserved)
25 NC No connection (Reserved)
1
13
25
14
This interface can be either RS-232C or RS-422. Connects GP to Host (PLC).