Chapter 3 - Installation and Wiring
GP-2400/2500/2600 Series User Manual 3-7
1) Be sure that the GP’s power cord is not plugged in to the power supply.
2) Remove the Terminal Strip’s clear plastic cover.
3) Remove the screws from the three (3) middle terminals, position the Ring
Terminals as shown above and reattach the screws. (Check each wire to make
sure the connections are correct)
4) Reattach the Terminal Strip’s clear plastic cover.
A torque of only 0.5 to 0.6 N•m is required to tighten an attachment screw.
L
AC Input Live Line
N
AC Input Neutral Line
FG
Grounding Terminal connected to
the GP chassis.
Connecting the Power Supply Terminals
+
Positive electrode
-
Negative electrode
FG
Grounding Terminal connected to
the GP chassis.
GP2500-TC11, GP2600-TC11
Power
Terminal
Block
LNFG
GP2400-TC41-24V
GP2500-LG41-24V, GP2500-SC41-24V,
GP2500-TC41-24V, GP2600-TC41-24V